Woodway Bariatric Medpro Treadmill

Woodway Bariatric Medpro Treadmill

Brand/Manufacturer: WOODWAY USA INC
Save

Woodway Bariatric Medpro Treadmill is designed specifically for bariatric patients. The Medpro Treadmills provide patients with an excellent way to exercise. With a wide range of speeds and inclines, patients are able to complete cardio workouts at a customizable pace. The ball-bearing transportation system allows for safe and effective movements while the soft, rubber running surface eliminates harmful foot strike shock.

Item # Desc Pkg Price
560398 With Full Handrail Each
$26722.95
$24293.59
560399 With Parallel Bar Handrail System Each
$30645.15
$27859.29

Woodway Medpro Treadmill Features

Technical Data-
Mechanical Data:


  • Overall dimensions: 6 ft. (L) x 2.85 ft. (W) x 4 ft. (H)
  • Weight: Approx. 485 lbs
  • Stand: four (4) rubber feet
  • Maximum load-bearing capacity: 500 lbs running, 800 lbs walking
  • Speed range: 0 to 12.5 mph
  • Incline range: 0 to 25%
  • Running mat acceleration: with Data-monitor fully adjustable up to maximum speed

Electrical Data:



  • Mains connection: 230 V AC 16 A, 50/60 Hz
  • Motor: DC with tachometer 1 KW
  • Drive: threaded rod and pinion
  • Resolution: 0.1 %
  • Lifting motor: DC motor 150 W
  • Mains cable: 2.5 m, 2 pole CEE 7/7 (earthed safety plug)
  • Main fuse: 10 A slow-acting fuses, 0.5 x 2 cm (in control)
  • Fuse for lifting drive: 5 A slow-acting fuses, 0.5 x 2 cm (in control

Treadmill Data:



  • General: 60 slats, width 43 cm, replaceable Running mat type rubber on aluminum support
  • Hardness of mat: approx. 40 Shore D
  • Mat surface: 156 cm x 43 cm
  • Color: Grey
  • Support system: 106 ball bearings with 12 V-belt guides
  • Lateral play: +/- 2 mm


Woodway Bariatric Medpro Treadmill User Guide

 

 

More Information

Safety Features-
Magnetic Emergency Stop Switch (Lanyard System)-
  • The magnetic emergency stop switch consists of a contact-free switch (break contact) which is mounted on the WUS/data monitor or on the handrail.
  • The circuit is closed through a magnet. The magnet is connected with a line, which is attached at the clothing of the runner by a clip. As soon as the magnet tears off of the contact-free surface, an interruption of the 230 V - mains supply will be caused and an emergency stop will be initiated. The magnet has to be placed on the red surface within the yellow circle.
  • The magnetic emergency stop switch has to be connected with the runner through the line and clip whenever the treadmill is being used.
Emergency Stop Switch on Handrail-
  • The emergency stop switch (mushroom-shaped) is mounted beside the right handrail and is to be used in an emergency. Pressing the emergency stop switch will interrupt the 230 V - mains supply and initiate an emergency stop. Can release the emergency stop switch by raising the red mushroom head.
Emergency Abandonment-
  • In emergencies the treadmill is abandoned in a different way. First jump straddle onto the side-covers in order to let the running-surface move freely underneath the legs. Then stop the treadmill with the normal stop or with one of the emergency stop devices.
Current Limiting of the Belt Drive-
  • The treadmills are equipped with a current limit control function, which reduces power consumption and increases safety. Main feature is the current limiter after time overflow.
  • This means, if the running belt is blocking for more than 10 seconds (this means the motor current limit is exceeded) the motor current will be reduced to 6 A. This is always recommended in case something gets caught in the belt so that the belt will stop automatically. Once the current limit control has been triggered, the torque of the motor is reduced to a minimum to prevent damage to the motor and electric system.
  • Key-Points Of Medpro Treadmill:

    Bearings-

    • Almost all of the bearings used in the treadmill are Pre-lubricated and do not need to be greased initially. On a yearly basis, the four bearings located at the front and rear shaft will need to be lubricated.

    Running Belt-

    • The teeth on the bottom of the running belt are Pre-lubricated to aid in reducing noise. There is no need to lubricate the teeth. If running belt is rubbing against the side of the drive pulleys, then a small amount of grease (i.e. Molykote or equal) on the edges of the belt slats will help reduce noise.

    Drive Belt-

    • As in the case of the running belt, the application of grease on the edge of the drive belt is only needed to reduce belt squeak and should be used sparingly.

    Incline System-

    • The incline systems on Woodway Treadmills are greased at the factory. If utilized for many hours or in a very dusty environment, system will need to be checked. If needed, apply a small amount of grease on chains and incline drive racks.


    Description of Treadmill Controls-
    Overview and Basic Functions
    • The Woodway Treadmill control is equipped with various elements which adjust the speed and incline systems, allowing for complex control sequences and carrying out of safety and monitoring functions together with pulse measurement.
    • The hardware consists of a micro-controller system based on the SAB80C537 with peripheral switching to the motor control and sensory components and to the control interfaces.
    The following control units can be connected as options for parallel operation-
    • Function buttons (FASTER / SLOWER / UP / DOWN / STOP / FAST STOP
    • LED display for speed / incline / time / distance / pulse (in preparation) WUS (LCD touch display with menu guide and access to complex functions)
    • Chip card connection component in WUS
    • PC / ECG equipment or similar via serial interface (implementing various protocols) 
    • Measurement and control of speed
    • Measurement of time, distance, and pulse
    • Interpretation of control activities with safety priority control
    • Time control for running programs
    • Interactive pulse control
    • Entry and monitoring of parameters for limit and operating values
    • Operating hours counter for switch-on and running time, total distance, incline mode
    • Monitoring and safety functions

Warranty

Woodway guarantees the repurchase of Woodway Treadmill products for a period of up to four 4 years after original installation.

Customer Reviews

Please enter your and your friends email address below.
Fields marked with * are compulsory
 
*
*
*
*


Submit Cancel
The selected product information has been successfully emailed to your friend.

Thank you for using www.rehab-store.com

Close