Cardinal Health Kendall SCD 700 Smart Compression Controller

Cardinal Health Kendall SCD 700 Smart Compression Controller

Brand/Manufacturer: CARDINAL HEALTH
Save
Authorized Retailer Badge

Covidien Kendall SCD 700 Series Compression Therapy Pump delivers compression to the leg, foot, or both to aid in the prevention of Venous Thromboembolism (VTE), including Deep Vein Thrombosis (DVT) and Pulmonary Embolism (PE) in the at-risk patient. It includes a flexible and transportable design, animated alerts with resolution prompts for any error, low noise, ease of cleaning, and a large LCD screen for visibility. It applies intermittent pneumatic compression to increase venous blood flow - helping prevent deep vein thrombosis and pulmonary embolism in at-risk patients.

Kendall SCD 700 Series Compression Therapy Pump Includes

  • The controller
  • Tubing sets (provided with the controller)
  • Single-patient use leg sleeves and foot cuffs (purchased separately)

Item # Desc Pkg Price
29525 SCD 700 Series Controller Each
$2809.95
$2161.49

Kendall SCD 700 Series Compression Therapy Pump Features


Smart Compression Cycles

  • Measure venous refill time using Vascular Refill Detection (VRD) technology and customize compression cycles automatically for each patient
  • Move 100% more blood per hour
  • Adjust accordingly when a patient’s needs change over time


Smart Patient Compliance

  • Displays the patient’s true wear time by nursing shift 
  • Features Patient Sensing technology, which alerts the nurse of removed sleeves 
  • Provides a wear time tool to support true compliance to therapy and quality improvement initiatives

How does SCD 700 Sequential Compression System works?

  • An 11-second default compression cycle is applied to the patient’s leg.
  • The sleeve deflates, holding 6 mmHg of pressure in the middle chamber of the calf.
  • Pressure is held and monitored for up to 60 seconds to allow evaluation of calf girth changes.
  • When calf girth stops increasing for 10 seconds, this signals that leg veins have refilled completely.
  • Vascular refill time is calculated and set; the sleeve deflates.
  • Vascular refill time is reevaluated every 30 minutes to account for patient variables.

Indications

  • Deep vein thrombosis prophylaxis
  • Pulmonary embolism prophylaxis
  • The system with foot cuffs is indicated for:
    - Circulation enhancement
    - Deep vein thrombosis prophylaxis
    - Acute and chronic edema
    - Extremity pain incident to trauma or surgery
    - Leg ulcers
    - Venous stasis/venous insufficiency

Contraindications

The Kendall SCD 700 system may not be recommended for use with leg sleeves for patients with:

  • Any local leg condition in which the sleeves may interfere:
    - Dermatitis
    - Vein ligation (immediate postoperative)
    - Gangrene
    - Recent skin graft
  • Severe arteriosclerosis or other ischemic vascular disease
  • Massive edema of the legs or pulmonary edema from congestive heart failure
  • Extreme deformity of the leg
  • Suspected pre-existing deep venous thrombosis


The system may not be recommended for use with foot cuffs on patients with:


  • Conditions where an increase of fluid to the heart may be detrimental
  • Congestive heart failure
  • Pre-existing deep vein thrombosis, thrombophlebitis, or pulmonary embolism

SCD 700 Smart Compression Controller Specifications

Particulars Details
Safety Standards Built to UL60601-1, CSA-C22.2 No. 601.1-M90, CSA C22.2 N0. 60601-1: 2008, JIS T 0601-2-204, EN60601-1, ANSI/AAMI ES60601-1:2005 and IEC 60601-1-2:2007 Standards UL Classified File # E189131 and E351453
Mode of Operation Continuous
Compression Type Leg Sleeves: Sequential, Gradient, Circumferential; Foot Cuffs: Uniform
Compression Cycle Leg Sleeves: 11 Seconds Compression; Foot Cuffs: 5 Seconds Compression Decompression time based upon Vascular Refill Detection measurement
Set Pressure

Leg Sleeves: 45 mmHg
Foot Cuffs: 130 mmHg

Adjustable Bed Hook

Yes

Power Cord Storage

Yes

Audible/Visual Errors

Low Pressure, High Pressure, Internal Electronics Malfunction

Power Cord

13 feet long with region specific appropriate cordage and plug

Controller Dimensions

Height: 6.8 inches (17.3 cm)
Width: 7.7 inches (19.6 cm)
Depth: 4.5 inches (11.4 cm) (when placed on a foot board)
Depth: 7.3 inches (18.5 cm) (free standing)

Controller Weight

5.0 lbs. (2.3 kg)

Power Requirements

100-240 VAC, 50VA, 50/60 Hz

Battery

10.8 V, 2200mAh, Lithium Ion pack
Run Time: 6-8 hours
Charge Time: 4 hours (charging only)

Tubing Set

Included, set of two individual assemblies

Operating Conditions

Temperature: 10°C to 40°C
Relative Humidity: 85% Maximum, non-condensing
Atmospheric Pressure: 700 mbar to 1060 mbar

Operation & Service
Manual

Included as either CD or Paper Manual

Customer Reviews

Please enter your and your friends email address below.
Fields marked with * are compulsory
 
*
*
*
*


Submit Cancel
The selected product information has been successfully emailed to your friend.

Thank you for using www.rehab-store.com

Close