Prius Healthcare Rhythm Turn Mattress System

Prius Healthcare Rhythm Turn Mattress System

Brand/Manufacturer: PRIUS HEALTHCARE USA
Save

Prius Healthcare Rhythm Turn Mattress System is a low-air-loss (LAL) pressure relief mattress system that provides continuous lateral rotation therapy, which helps mobilize secretions and other body fluids during pulmonary treatment related to immobility. It provides continuous lateral rotation therapy in two different degrees (20 degrees and 40 degrees), which gently turns the patient from side to side to significantly lower the risk of infection, pneumonia and other pulmonary complications

Prius Healthcare Rhythm Turn Highlights

  • Low slip base cover to keep the mattress in place
  • Effective micro low air
  • Nylon woven fabric
  • CPR for quick deflation
  • Cable management for patient safety

Item # Desc Pkg Price
PHR-RHYT36Q Rhythm Turn Mattress System, 36 Inch Each
$4924.25
$3787.89
PHR-RHYT42Q Rhythm Turn Mattress System, 42 Inch Each
$6113.25
$4702.49
PHR-RHYT48Q Rhythm Turn Mattress System, 48 Inch Each
$6652.85
$5117.59

Prius Healthcare Rhythm Turn Mattress Features

  • 8 Inch air cell mattress replacement
  • Low air loss therapy 20 and 40 degree lateral rotation with side perimeter and static therapy
  • Auto Firm provides immediate firm surface
  • High vapor permeable and quilted nylon cover
  • 2 Inch convoluted foam base 
  • Integrated glide sheet to base cover for easy transferring
  • Visual and audio alarm for low pressure and power failure with alarm mute function
  • Keypad lock out function
  • 10 Digital comfort setting
  • Modularized design for air mattress
  • Integrated power cable retainer
  • Quick CPR deflation within 20 seconds

How to use Prius Healthcare Rhythm Turn Mattress System?

  1. Remove the existing mattress from the bed frame
  2. Replace the standard mattress with Low Air Loss Turning Mattress Replacement system and make sure the mattress is positioned so the air tube is at the foot of the bed
  3. Secure the straps beneath the mattress to the bed frame
  4. Hang the Master Control Unit on the footboard of the bed frame. Attach the air tube connector to port on the left panel of the Master Control Unit. Be careful on the color matching between the connectors and socket. (black connectors to black socket, red connector to red socket)
  5. Make sure the air hoses are not kinked under the mattress. (Could be verified by simple visual check) For detail Air hose connection please refer Explode Diagram
  6. Zip the low shear top cover to the mattress. The top cover should be loosely fit to the mattress
  7. Carefully plug power cord into a properly grounded power source. Turn on the master mechanical power switch on the right side panel. The STANDBY LED should illuminates.
  8. Push the STANDBY/OPERATE button of the front panel. The OPERATE LED should now be lighted up and the Master Control Unit should now start to spin
  9. Push the AUTO FIRM button for fast inflation. Allow 4 ~ 7 minutes for full inflation. After the mattress is fully inflated, the caregiver can now transfer the patient on to the mattress. Push the AUTO FIRM again to release the fast inflation mode. (Note: The mattress can be inflated with patient lying on top)
  10. Static Function: Push the static button and adjust the Contort Control by pressing the SOFT/FIRM button to achieve the maximum patient comfort. On this mode the system provides True Low Air Loss therapy. Perform a hand check by placing hand under the patient buttocks between cells and foam. The patient should have at least 4 cm of clearance between the buttocks and the bottom of the mattress.
  11. Turning time can be adjusted by the CYCLE button. The time can be adjusted from 3 minutes to 95 minutes. (When Static Function is selected, the timing window would not show any digits)
  12. The Master Control Unit is equipped with power failure alarm. With this function enabled, the Control unit generates a horn sound to signal to caregiver that main power failure. The alarm can be disabled by pushing the Alarm Reset Button on the front panel
  13. LOCK-OUT: The Master Control Unit is also equipped with a manual locking-out function. All function keys will be automatically disabled if the LOCK –OUT button has not been activated. When lock-out has been engaged, the “LOCK OUT” button will illuminate. UNLOCKING Unlocking the control panel is easy. Simply press the “LOCK OUT” button on the control panel for 3-5 seconds or recycle the power by turning off and on the main power switch
  14. 20 degrees turning function can be activated by pressing the “TURN” and select desire turning therapy. “LEFT TURN” allows the mattress to turn to left and back to horizontal. “RIGHT TURN” would have the same effect but turning to the right. The “FULL TURN” allows for full function of turning to left and right and should always activate with timer setting. The timer can be set by “CYCLE” button
  15. 40 degrees turning function can be activated by pressing the “BT” button and follow the operation instruction on step 14.

Cleaning


  • The Mattress
    - The mattress should be cleaned weekly using a damp soft cloth and mild detergent. If top sheet (Top cover) or base (Bottom cover) becomes overly soiled, put on clean gloves, plastic gown and eye protection before removing top sheet or base and dispose of according to standard in function control procedures. Replace with clean covers.
  • The Master Control Unit
    - The master control unit should also be cleaned weekly using a damp soft cloth and mild detergent. The blower casing is manufactured from ABS plastic and if the case is soiled the blower can be wiped down with a sodium hypochlorite solution to dilution of 1000ppm or any EPA- approved hospital grade disinfectant. (NOTE: Do not use phenol base cleaning solution.) The air filter should also be cleaned and checked as often as possible at a minimum of every six months. Air Filter can be removed by pinching center of the filter and pulling outward from the back of the Therapy control unit.


Storage and Care



  • Master Control Unit
    - Check the power cord and plug for abrasions or excessive wear
    - Plug in the unit and verify air flows from the units hose connection ports
    - Place in plastic bag for storage
  • Mattress Replacement
    - Check the air manifold for kinks or breaks and replace if necessary.
    - Pull out the CPR plug at the head of the mattress and disconnect the air feed tubes. All the air will now be expelled. Starting at the head end, the mattress can now be rolled. Use the base mounted straps for containment
    - Place in plastic bag of storage.

Prius Healthcare Rhythm Turn Mattress System User manual


Specification

Control Specifications Values
Dimension (L) 17.7" x (W) 6.8" x (H)10.8"
Weight 13.8 lbs
Cycle Time 3~95 min
Min Operating Pressure 10 +/- 3mmHg
Max Operating Pressure 61 +/- 4mmHg
Flow-rate N/A
Rated Voltage AC 110-120V
Rated Frequency 60 Hz
Fuse Rating 5A 250V
Max Current 5A
Classification Class I, Type BF
Operation Temperature 15°C (59°F)~35°C (95°F)
Operation Humidity 30% ~ 75%
Matterss Specification Values
Dimensions (L)36" x (W)80" x (H)10"
Weight 37.4 lbs
Cell Number 18 cells
Cells Material Nylon Coated with PU
Cover Type Zipper Cover
Cover Material Nylon Woven fabric w/PU coating finish
Base Material Woven Polyester fabric w/PVC backing

 

Warranty

Up to 12 months from the date of delivery