Drive Med-Aire Alternating Mattress System with Low Air Loss

Drive Med-Aire Alternating Mattress System with Low Air Loss

Brand/Manufacturer: DRIVE MEDICAL
Save
Authorized Retailer Badge
  • HyGiene Products
  • Non Returnable
  • Free Shipping no minimum

Drive Med-Aire Alternating Mattress System with Low Air Loss offers both alternating pressure and low air loss to optimize pressure redistribution, shear or friction reduction, and microclimate control. It is designed to prevent, treat and heal pressure ulcers in the home or long term care setting. The mattress system operates in both alternating and static pressure modes.

What does Med Aire Low Air Loss Mattress Replacement System Includes?

  • Low Air Loss Mattress
  • Cover
  • Pump
  • 1 Year Limited Warranty

 

Item # Desc Pkg Reward Price
14027 Med-Aire Mattress System Each $11.72
$479.99
$390.61

Drive Alternating Pressure Mattress Features

  • Control unit offers 10 minute cycles when alternating and can also be used in static mode
  • Adjustable patient weight settings allow for optimal immersion and patient comfort and compliance
  • Audio and Visual alarm alerts when air pressure is low
  • System includes 20 individual air cells to maximize immersion and envelopment with pillow feature for head stability and comfort
  • 8-inch deep air cells are easily removed and replaced with air leakage plugs
  • Removable Nylon stretch cover is fluid resistant, low shear and vapor permeable helping protect the skin from friction and moisture
  • The comfortable mattress system has CPR valve which allows for rapid deflation
  • Tubing quickly and easily disconnects with EZ Lock/Quick Release design
  • The LED and audible alarms provide critical performance date and alert a caregiver when the pressure falls below 10mmHG

Med-Aire Alternating Mattress System User Manual

What buy with Med-Aire Pump and Mattress System

Functions of Drive Medical Med Aire Low Air Loss Mattress

Control Unit Functions

  • Power switch: It is located on the side of the control unit. Use the power switch to turn the system off and on
  • Analog Pressure Dial: Adjust the dial to correspond to the patients’ appropriate weight setting or comfort level
  • Static Pressure Button: Press the static pressure button to discontinue alternating therapy
  • Mute Button: Silences the audible portion of the low-pressure information signal

Mattress Functions

  • CPR deflation valve: Pull the red CPR strap to release the air immediately from the mattress for rapid deflation. Deflation time varies depending on patient weight and profile
  • Quick Connector: Used to connect the therapy mattress to the control units

How to Clean Med Aire Alternating Pressure Mattress System?

Control Unit

  • UNPLUG the control unit from its power source prior to cleaning.
  • Check for external damage and move the control unit to the cleaning area.
  • Place the control unit on a work surface and wipe the outside of the case with a clean cloth to remove any dust or particles. Make sure all areas are clean (top and bottom, both sides).
  • Spray cloth with cleaning solution and clean faceplate and control unit casing. DO NOT allow excess cleaning solution on faceplate or control panel. (If solution gets inside, the damage will occur.)
  • After the control unit is thoroughly cleaned and dried, proceed to plug in the control unit and test for normal functioning.
  • Unplug the control unit and store with proper identification tag until needed for use.
  • Avoid long exposure to sunlight.

Mattress

  • Remove any soiled or used bedding.
  • Examine the mattress for visible soilage of bodily fluids. If no disinfection is required, brush off or wipe down all surfaces of the cover sheet with soap and water before wetting with any liquid disinfectant.
  • If disinfection is required, follow the procedure below: - Use rubber gloves and eye protection. - Unzip the top cover from the mattress. - Prepare detergent/disinfectant solution (registered by the EPA recommended) according to the preparation recommended for correct use-dilution. - 1:9 Bleach and water dilution may be used. - With the mattress fully deflated, wipe down all surfaces around and in between the air cells, including the cells. - Covers may be immersed and soaked in disinfectant for the required incubation period. After presoaking, the cover may be rinsed through a regular cycle in a washer with no soap then laundered with mild detergent (wash temperature 93°F/34°C, rinse temperature 78°F/26°C or on the coldest setting). - Allow all covers and parts to aerate until they are fully dry.
  • Repeat the process with the tubing set: spray/wipe, incubate, and air dry. Dry the mattress on a flat surface area after cleaning, away from exposure to the sun.
  • Avoid long exposure to sunlight

Specification

Particulars

Specifications

Control Unit Airflow

8 LPM (Liters per Minute)

Control Unit Cycle Time

10 minutes

Control Unit Type

Compressor

Control Unit Alarms

Visual/Audible

Mattress Cover Material

Fluid Resistant Nylon

Weight Capacity

350lbs

Warranty

1 Year limited warranty