Nestle Compat Dualflo Enteral Feeding Pump is an easy to use, versatile device for the administration of all enteral feeding solutions. It is an advanced delivery system designed to administer tube feeding formula and water for patient hydration. Users can program the pump to provide individualized patient hydration protocols, automatic flushes of the feeding tube or formula at pre-set strength.

Features

  • Nestle Compat Dualflo Enteral Feeding Pump features automatic priming of the delivery-set
  • Delivery-set security doors reduce the chance of set dislodgement and alarms and stops the pump if opened during normal operation
  • Memory features lifetime retention of infusion rate, dose limit, formula strength, water volume set, time interval, formula and water delivered and accumulated volume
  • Audio and visual alarms include occlusion or empty container, dose complete, low battery and open delivery set door
  • Water volume set interval: 0ml to 500ml in 1ml increments, 2 to 12 hours in 1 hour increments
  • Large LED display window, alternates displaying delivery rate and volume delivered when pump is running
  • Battery lasts upto 8 hours at 100ml per hour and is rechargeable while pump is operating
  • Self-diagnostic mode allows for complete circuitry check when pump is turned on
  • Dose limit for Intermittent Feeding with choice of 3 dose complete alarm modes
  • Ability to quickly view formula and water settings without interruption of feeding
  • Lightweight and portable, the pump is 7lb and can clamp to any IV pole
  • Formula strength: FS (Full Strength), 3/4, 2/3, 1/2, 1/3, 1/4
  • Flow rate accuracy: +/- 10% of selected flow rate
  • Infusion rate: 1 to 295ml/hr in 1ml increments
  • Smooth surface of pump makes cleaning easy
  • Adjustable alarm volume control knob
  • Adapter cap holder
  • Also available:
    - Instruction Manual

More Information

  • Caution:
    - Not for parenteral use
    - Intended exclusively for enteral tube feeding and patient hydration
  • Patient Hydration with Automatic Flush:
    - Patient hydration needs are facilitated by administering up to 500 mL of water over a selected time interval (in hours). Time interval is adjustable in 1 hour increments from 2 to 12 hours. In addition, the final 25 mL of water is automatically flushed through the line just before the conclusion of the time interval.
  • Delivery Set Security Doors:
    - Reduces the likelihood of accidental dislodgment of sets and enables immediate detection of a free flow condition.
  • Automatic Priming:
    - Automatic priming of formula and water through the administration set allows nurse time to perform other bedside duties and may help reduce wasted sets due to improper manual priming.
  • Formula Dilution:
    - Provide formula dilution when necessary by selecting Formula Strength. Formula can be delivered at full strength (FS), or diluted to 3/4, 2/3, 1/2, 1/3, 1/4 strength, or H20 (all water delivery, no formula).
  • Programmable Flush after Dose is Delivered:
    - Deliver up to 500 mL of water in a programmable water delivery to hydrate the patient or flush the line after the formula dose limit is delivered. Water is delivered at a fixed rate of 375 mL/hr.
  • Versatility:
    - Formula rate adjustable in 1 mL/hr increments from 1-295
    - Dose Limit adjustable in 1 mL/hr increments from 1-2000
    - Formula Strength options include FS (Full Strength), 3/4, 2/3, 1/2, 1/3, 1/4 strength, or H20 (water only)
    - Water volume adjustable in 1 mL/hr increments from 0-500
    - Time Interval adjustable in 1 hour increments from 2 to 12 hours, with programmable flush available as dose is delivered
    - Ability to select basic full strength formula delivery when water delivery options are not desired
  • Lifetime Memory Retention:
    Infusion Rate, Dose Limit, Formula Strength, Water Volume Set, Time Interval, Formula and Water Volume Delivered, and Accumulated Volume are automatically recalled when the pump is turned back on
  • Audio and Visual Alarms when Pump is Turned On:
    - Feed Error for detecting empty container or occluded line
    - 21/2 minute Hold Alarm if user forgets to start the pump
    - Dose Delivered
    - Low Battery
    - No Set